Colo Enviro LabsEnvironmental testing · Navi Mumbai Request a quote

Environmental testing lab · Navi Mumbai

Measured proof that your data centre air, surfaces and water are within spec.

Colo Enviro Labs tests particle cleanliness, gaseous corrosion, indoor air quality, water and thermal performance for data centres, cleanrooms and critical facilities. You get readings you can defend in an audit, a customer review or a warranty claim.

Lab at Goodwill Bizhub, MIDC Pawne, next to IKEA Turbhe, Navi Mumbai

What we test

Five test families, built around how data centres actually fail

Contamination damage builds slowly. Zinc whiskers, sulfide films on silver, dust that turns conductive at high humidity and scale in cooling towers rarely raise an alarm until hardware fails. Each service below targets one of those failure routes.

Handheld laser particle counter showing channel counts at 0.3, 0.5 and 5.0 micron CH SIZE COUNT/m³ 1 0.3µm 41 206 2 0.5µm 12 480 3 5.0µm 106 ISO 14644-1:2015 ISO 14644-1 · ASHRAE TC 9.9

Particle count & cleanroom classification

Airborne particle counts at 0.3 to 10 µm, sample locations per ISO 14644-1:2015 Table A.1, class certificate for data halls, cleanrooms and pre-IST handover.

Particle testing →
Corrosion classification coupon card with copper and silver strips for ISA-71.04 testing CCC · 30-DAY EXPOSURE CuAg ANSI/ISA-71.04-2013 ASTM B825 ANSI/ISA-71.04-2013

Gaseous corrosion & reactivity monitoring

30-day copper and silver coupons at intake, supply and return air. Results give G1 to GX severity and point to the gas family causing it.

Corrosion testing →
Multi-parameter indoor air quality monitor showing CO2, PM2.5 and TVOC CO₂642 ppm PM2.511 µg/m³ TVOC186 µg/m³ ISHRAE 10001 · ASHRAE 62.1

Indoor air quality (IAQ)

CO₂, CO, PM2.5, PM10, TVOC, formaldehyde, temperature and humidity in NOCs, offices and control rooms, with ventilation advice.

IAQ testing →
Water chemistry bench with conical flask, test tubes and Legionella culture plate ISO 11731 IS 10500:2012 · cooling tower · chilled water IS 10500 · ISO 11731

Water, cooling tower & Legionella

Potable, cooling tower, chilled water, humidifier feed, STP outlet, fire water and liquid cooling fluid. Chemistry and microbiology done in-house.

Water testing →
Infrared thermal image of a server rack showing a hot spot at the top of the rack 33.8 °C top inlet 21.4 °C bottom inlet ASHRAE18 to 27 °C ASHRAE · NFPA 70B

Thermal, airflow & pressure mapping

Rack inlet mapping at three heights, tile airflow, room differential pressure, IR thermography of electrical panels, lux and noise.

Thermal mapping →
Raised floor perforated tile airflow and room differential pressure measurement ΔP+5.2 Pa tile flow612 CFM under-floor plenum 12 INSTRUMENT LINES

Our lab & equipment

See the instruments we use, how samples reach the lab, how calibration is controlled, and how to find us next to IKEA Turbhe.

Lab & equipment →

Why it matters in Mumbai and Navi Mumbai

Local air is harder on electronics than most design briefs assume

Navi Mumbai's data centre belt sits beside the Thane-Belapur and Taloja industrial areas, the Thane creek and the Arabian Sea. That puts three things into the air your fresh-air units pull in: sulfur compounds from industry and diesel traffic, chlorides carried on sea air, and fine dust from construction that never seems to stop.

Since the move to lead-free (RoHS) boards, silver and copper on circuit boards react with sulfur to form creep corrosion that can short components. The monsoon then lifts indoor humidity, and dust that was harmless at 40% RH starts to absorb moisture and conduct.

None of this shows up on a BMS screen. It shows up as unexplained hardware failures 18 months later. Periodic testing is how you see it early and fix the filtration, pressurisation or cleaning schedule before it costs you a server.

RiskWhat we measureTypical fix
Sulfide and chloride filmsCu and Ag coupon film thicknessChemical filtration, sealing intakes
Conductive or hygroscopic dustParticle counts, gravimetric dustFilter upgrade, deep cleaning
Dust entering from corridorsRoom differential pressurePositive pressure, door seals
Hot spots and recirculationRack inlet temperature at 3 heightsBlanking panels, tile layout
Scale, corrosion, LegionellaWater chemistry and cultureDosing correction, disinfection

How an engagement runs

From your first call to a report your auditor accepts

  1. Scope

    You share drawings, room areas and the limits in your SLA or design basis. We confirm the standard and occupancy state.

  2. Sampling plan

    We fix the number and position of test points, sample volumes and timings, and send a method statement for your permit.

  3. Site work

    Calibrated instruments, logged on site with location IDs. Water and coupon samples are sealed and kept under chain of custody.

  4. Lab analysis

    Samples are analysed at our Navi Mumbai lab. Field data is checked against instrument calibration and blanks.

  5. Report & review

    Raw data, floor plan with points, pass or fail per location, likely causes and corrective actions. We walk your team through it.

Standards we test against

Your limit, your standard, stated on every report

We do not invent pass marks. Each report names the clause and edition used, so results can be compared year on year.

ISO 14644-1:2015ISO 14644-2:2015ANSI/ISA-71.04-2013ASTM B825ASHRAE TC 9.9 thermal guidelinesASHRAE particulate & gaseous guidelineASHRAE 62.1ISHRAE 10001:2019IS 10500:2012ISO 11731 (Legionella)ASHRAE 188ISO 4406 fluid cleanlinessNFPA 70BMPCB consent norms

Why teams trust the numbers

Reports an auditor can trace, line by line

No marketing-grade “all clear”. Every figure on a CEL report ties back to an instrument, a method and a limit you chose.

ISO/IEC 17025

Quality system, NABL in progress

Built to ISO/IEC 17025, with NABL accreditation under way. Until the scope is granted we say so plainly and our reports carry no NABL mark.

TRACEABLE

Calibrated, traceable instruments

Each instrument’s serial number and calibration due date is printed on your report, traceable to national standards. Past-due instruments are tagged out of service.

RAW DATA

Raw readings, not just a verdict

Every report gives raw readings, sample locations, the method, the clause and the measurement uncertainty — so your team or auditor can re-check each number.

INDEPENDENT

Independent of the cleaning crew

Testing is most useful when it is not done by whoever cleaned or built the space. We report raw counts and locations even when the site was cleaned by our group company.

CHAIN OF CUSTODY

Chain of custody & field blanks

Coupons and water samples carry a chain of custody from site to bench, with field blanks and duplicates on each batch.

SAMPLE REPORT

See a sample report first

Want to see the format before you commit? Ask for a redacted sample report for your test type.

Request a sample report →

Questions we get asked

Frequently asked questions

What does an environmental testing lab do for a data centre?
We measure the things that quietly shorten hardware life or fail an audit: airborne particles against ISO 14644-1, corrosive gases using copper and silver coupons against ANSI/ISA-71.04, rack inlet temperature and humidity against the ASHRAE envelope, room pressure and tile airflow, indoor air quality in occupied areas, and the water in cooling towers, chilled water loops and potable lines. Each test ends in a report with raw readings, locations and pass or fail against the limit you specified.
Is Colo Enviro Labs NABL accredited?
Our quality system is built to ISO/IEC 17025 and we are working through NABL accreditation. Until the NABL scope is granted, our reports do not carry the NABL mark. Every report still states the test method, instrument serial number, calibration certificate reference and measurement uncertainty, so your auditor can trace each number.
Can you test a live data hall without disrupting operations?
Yes. Particle counters, thermo-hygrometers, anemometers and thermal cameras are battery powered and non-contact. Our technicians work under your permit-to-work and method statement, follow ESD and hot-aisle safety rules, and never open, touch or move IT equipment. Most data hall surveys are completed in one shift.
How long does it take to get results?
Typical turnaround: particle count and thermal surveys, report within 5 working days of the site visit. Corrosion coupons, 30 days of exposure plus about 7 working days of analysis. Water chemistry, 3 to 5 working days. Legionella culture, 10 to 14 days, because the ISO 11731 method needs up to 10 days of incubation.
Which locations do you serve?
Our lab is in Navi Mumbai, a short drive from the data centre campuses in Mahape, Airoli, Rabale, Ghansoli, Juinagar, Turbhe and Taloja. We send field teams across Mumbai, Thane and Pune, and travel pan-India for project work and commissioning.
Who should own environmental testing: the operator, the contractor or a third party?
The operator should own the schedule and the limits. Testing works best when it is done by someone independent of the person who cleaned or built the space. CEL is a group company of Colo Techxpert Solutions, which provides specialist data centre cleaning. When we test a site CTS has cleaned, our report shows raw counts, sample locations and instrument IDs, so your team or auditor can check the numbers themselves.

Request a test plan

Tell us the site, the rooms and the standard you have to meet.

We reply within one working day with a sampling plan, the number of test points, turnaround and a fixed quote. Site visits across Mumbai, Navi Mumbai, Thane and Pune, and pan-India on project basis.

Emailinfo@coloenvirolabs.com
Phone+91 96395 35455
WhatsAppChat on WhatsApp
LabGoodwill Bizhub, MIDC Pawne, Thane-Belapur Road, Navi Mumbai 400703
LandmarkNext to IKEA Navi Mumbai, Turbhe