Thermal, airflow and pressure mapping for data centres

Find hot spots, bypass air and pressure problems before they cost cooling capacity or equipment. Includes IR thermography of electrical panels, plus lux and noise surveys for occupied areas.

Rack inlet 3 heights per rackPressure ±0.1 Pa resolutionThermography radiometric images

What a thermal and airflow survey finds

Most data halls are overcooled on average and undercooled in specific places. The BMS reports return air temperature at the CRAH, which says little about what a server at the top of rack 14 is breathing. A rack-level survey shows where cold air is wasted and where hot air is coming back.

  • Rack inlet mapping at bottom, middle and top of each rack, against the ASHRAE envelope
  • Perforated tile airflow in CFM using a capture hood, compared with the rack load it serves
  • Under-floor static pressure and room differential pressure to corridors and adjacent rooms
  • Hot aisle and cold aisle containment leak checks
  • IR thermography of LT panels, bus ducts, PDUs, UPS and battery strings, with a severity rating for each anomaly
  • Lux and noise in data halls, plant rooms and offices, for safe working and statutory records
Infrared thermal image of a server rack showing a hot spot at the top of the rack 33.8 °C top inlet 21.4 °C bottom inlet ASHRAE18 to 27 °C
A thermal image of a rack inlet. Warm air at the top shows recirculation over the rack, which a mid-height sensor would miss.
Raised floor perforated tile airflow and room differential pressure measurement ΔP+5.2 Pa tile flow612 CFM under-floor plenum
Tile airflow and room pressure are measured together. A room that drifts negative pulls corridor dust into the data hall.

Thermography severity guide

Temperature rise of a component compared with a similar component under the same load. We report the measured ΔT, load at time of test and the recommended action.

ΔT over similar componentSeverityRecommended action
1 to 3 °CPossible deficiencyMonitor at next scheduled survey
4 to 15 °CProbable deficiencyRepair at next planned shutdown
> 15 °CMajor discrepancyRepair immediately

Based on ANSI/NETA MTS temperature-rise guidance. Final priorities are set with your electrical team and the equipment manufacturer.

Thermal and airflow FAQs

Where should rack inlet temperature be measured?
At the air inlet of the rack, at three heights: near the bottom, the middle and the top. Top-of-rack inlets are where hot exhaust air most often recirculates over the rack, so a single mid-height reading can miss a real hot spot.
What is the ASHRAE recommended range for data centres?
The ASHRAE recommended envelope for most IT equipment is an inlet dry-bulb temperature of 18 to 27 °C, with a dew point between -9 °C and 15 °C and relative humidity no higher than 60%. Your equipment class or SLA may allow a wider allowable range.
How often should electrical panels have thermography?
NFPA 70B recommends infrared thermography of electrical equipment at least once a year, and more often for critical or heavily loaded equipment. In data centres we suggest twice a year for main LT panels, bus ducts and UPS output, ideally at peak load.
Why measure room differential pressure?
A data hall kept slightly positive to corridors and loading areas pushes air out through gaps instead of pulling dust in. Without measurement, a small change in fresh-air balance can turn the room negative and your particle counts rise for no obvious reason.

Request a test plan

Tell us the site, the rooms and the standard you have to meet.

We reply within one working day with a sampling plan, the number of test points, turnaround and a fixed quote. Site visits across Mumbai, Navi Mumbai, Thane and Pune, and pan-India on project basis.

Emailinfo@coloenvirolabs.com
Phone+91 96395 35455
WhatsAppChat on WhatsApp
LabGoodwill Bizhub, MIDC Pawne, Thane-Belapur Road, Navi Mumbai 400703
LandmarkNext to IKEA Navi Mumbai, Turbhe